You can specify the schedule number and execute a weld from the MANUAL FCTNS Manual Weld screen.
Table 1. MANUAL FCTNS Manual Weld Screen Items — Servo Gun
| ITEM | DESCRIPTION |
| Start Distance Sched: |
This item is the distance schedule number to start from for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
| Pressure schedule: |
This item is the pressure schedule number to use for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
| Weld schedule: |
This item is the weld schedule number to use for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
| End distance sched: |
This item is the distance schedule number to open to for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
| Weld ID: |
This item is the Weld ID number to use for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
Thickness: |
This item is the part thickness value to use for the current weld operation. To change this value, type the appropriate number, and press ENTER. |
| Weld Duration (ms) |
This item indicates the amount of time to execute the last weld. |
Table 2. MANUAL FCTNS Manual Weld Screen Items — Air Gun
| ITEM | DESCRIPTION |
|---|---|
| Equipment Number: |
If you have multiple equipment defined, then you will see this item and be allowed to choose which equipment you want to use to perform a manual weld. |
| Weld schedule: |
This is the actual weld schedule value that you want to send to the weld controller. |
| Weld duration(ms): |
This item indicates the amount of time to execute the last weld. |